Menu
PAR
Description
4.9
450
Undervoltage
Lets you change the Undervoltage value. Minimum and maximum default values depend on line voltage.
Menu
PAR
Description
4.10
454
Chopper ON
Corresponding to the threshold of activation of the braking resistor. It is so possible to increase this value just below the
Overvoltage threshold level (ADL300-...-4 = 802 Vdc, ADL300-...-2T = 396 Vdc, ADL300-...-2M = 396 Vdc).
Parameter's range are defined thru IPA 560 Mains voltage setting.
Note !
If Mains voltage is set at the maximum possible value, the activation threshold of the braking resistor can only assume the max value and can
not be changed.
Menu
PAR
Description
4.11
570
Password
You can enter a password to protect the parameters from unauthorized tampering: the password can consist of a com-
bination of a maximum of any 5 figures that can be selected by the user. All parameters are locked, except this one and
Save parameters.
Entering the password, press the E key, then enter the password and press the E key again to enable it (a password ena-
bled message (Enabled) is displayed).
So that the password remains valid even after switching the unit off and then switching it back on, save it using the Save
parameters command.
When the password is enabled any attempts to modify a parameter are blocked and the Password enabled message is
displayed.
To disable the password, enter the Password parameter (570) in the DRIVE CONFIG menu.
Check that the password is enabled (Enabled), press E and enter the combination of figures that make up the password.
Press E again. A message is displayed telling you the password is no longer enabled (Disabled).
To make sure the password continues to be disabled even after switching the unit off and then switching it back on, save
this configuration using the Save parameters command.
When an incorrect password is entered, the Password wrong message is displayed.
Menu
PAR
Description
4.12
586
Set passwd expert
Enables the password to protect change of the setting of parameter 554 Access mode from Easy to Expert. A value
other than 0 must be entered. Entering 0 disables the password.
You have to enter Expert mode to access parameter 586 Set passwd expert.
The password value must be entered twice to be accepted.
After the password is set, parameter 554 Access mode remains in Expert mode; to enable the protection, enter the pass-
word in parameter 566 Passwd expert.
Now parameter 554 Access mode will go to Easy mode. At every power-on, the drive will start in Easy mode with the
protection enabled.
Menu
PAR
Description
4.13
572
Application key
This parameter can be used to enter the key for enabling the PLC application.
You may need to enter a key to definitively enable some PLC applications. Please contact Gefran for details about which
PLC applications require the key.
If executing an application that envisages a key verification and the key is incorrect, enabling is forced for 200 hours (time
drive enabled).
In this phase a message is displayed informing you that the period of forced enabling time is about to expire.
At the first power-on after the 200 hours an alarm is generated and the application does not start.
Please contact Gefran for the numerical value of the key.
Menu
PAR
Description
4.14
574
Startup display
It is possible to set the parameter that will automatically be displayed when the drive is switched on.
If set to -1 the main menu is automatically displayed when the drive is turned on.
If set to 0 the display page is automatically displayed when the drive is turned on.
16
UM
Type
FB BIT
V
FLOAT
UM
Type
FB BIT
V
FLOAT
UM
Type
FB BIT
UINT32
UM
Type
FB BIT
UINT32
UM
Type
FB BIT
UINT32
UM
Type
FB BIT
INT16
ADL300 • Functions description and parameters list
Def
Min
CALCF
CALCF
Def
Min
CALCF
CALCF
Def
Min
0
0
Def
Min
0
0
Def
Min
0
0
Def
Min
-1
-1
Max
Acc
Mod
CALCF
ERWZS FVS
Max
Acc
Mod
CALCF
FVS
ERWZS
Max
Acc
Mod
99999
ERW
FVS
Max
Acc
Mod
99999
ERW
FVS
Max
Acc
Mod
4294967295
ERW
FVS
Max
Acc
Mod
20000
ERW
FVS

Advertisement

Table of Contents
loading

Table of Contents