CHAPTER 9 - EVENT CODES
Event Code
4069
4071
4072
4073
4074
4075
JANUARY 2023
Message Text and Description
Configuring the drive default
map ID was not possible.
Power supply fan failed.
No cleaning cartridge in
partition available for auto
cleaning.
Medium source element
empty.
Medium source element
empty.
Cartridge lost while extracting
it from slot/drive.
Details and Solution
Ensure the drive is powered up, is
communicating with the library, and
has up to date firmware. If this error
persists, contact Spectra Logic
Technical Support. See
Spectra Logic on
Verify the power supply fan is
spinning and ensure there are no
obstructions in the fan.
Auto cleaning is enabled, but the
partition contains no labeled
cleaning cartridge. The library was
unable to perform the auto clean
function for one or more drives in
this partition. Install a valid and
labeled cleaning cartridge into the
partition and then perform a load
and unload on the drive that needs
to be cleaned to initiate the auto
cleaning.
Check the source slot visually and
rescan inventory. Additionally check
for valid and readable barcode label.
Check the source slot visually and
rescan inventory. Additionally check
for valid and readable barcode label.
Check the source element and ensure
that there are no obstructions in the
pathway of the robot.