Spectra T50e Service Procedure Quick Reference

Hide thumbs Also See for T50e:

Advertisement

Quick Links

Service Procedure Quick Reference
Robotics
Replacement
T50e
Tools & Supplies

Estimated Time

ESD Protection

Library Power

Data I/O Operations

Robotic Movement

Admin./Superuser

BlueScale Login

Considerations

(continued next page)
Not a substitute for official published procedural guide
Detailed instructions/videos located at support.spectralogic.com
Replacement robotics
#1 Phillips screwdriver
USB flash drive (FAT32)
o For collecting Auto-support Log File (ASL)
60 minutes
Required
Off
Discontinue
Verify with customer that data I/O to all drives has halted
Discontinue
Verify robotic movement has halted
Verify with customer that move requests from host have been halted
Required
support.spectralogic.com has a downloadable video of this procedure under
"Service Partner Resources." A portal account is required
It is recommended that all tapes are removed from drives by customer before
procedure to avoid potential stuck tapes after power-up
Verify customer has a current backup of the following (if applicable):
o Library configuration
o MLM and DLM databases
o Encryption keys
Refer to the "Spectra T50e Robotics Replacement Instructions" service guide
for a list of information that should be documented/backed-up by customer
prior to service
If you attempt to remove magazines without depressing magazine release
buttons, internal magazine latches may break. This type of failure cannot be
repaired in the field and the library must be returned to Spectra Logic
August 2017 V2
Page 1 of 5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T50e and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Spectra T50e

  • Page 1 If you attempt to remove magazines without depressing magazine release buttons, internal magazine latches may break. This type of failure cannot be repaired in the field and the library must be returned to Spectra Logic (continued next page) August 2017 V2...
  • Page 2 If you attempt to remove magazines without depressing the magazine release buttons, the internal magazine latches may break. This cannot be repaired in the field, the library must be returned to Spectra Logic 3. Loosen screws securing front panel, then tilt front panel towards you ...
  • Page 3 Detailed instructions/videos located at support.spectralogic.com Service Procedure Quick Reference Robotics Replacement T50e Procedure Overview 9. Hold ribbon cables down and under base of replacement robotics (continued) 10. Align center slot in base of robotics with center guide rail in chassis, position robotics approx.
  • Page 4 Reinstall front panel, ensuring gear rail is correctly engaged to front panel (ref. step 13). Retest robotics and access port o If robotics and/or access port are still not functioning properly, contact Spectra Technical Support (continued next page) August 2017 V2...
  • Page 5 Service Procedure Quick Reference Robotics Replacement T50e Procedure Overview 28. Create an Auto-support Log File (ASL) and forward to Spectra Technical Support (continued)  Obtain permission from customer prior to performing this step  ASL’s do not contain sensitive customer information such as passwords, encryption keys etc.

Table of Contents