CHAPTER 9 - EVENT CODES
Event Code
2043
2044
2045
2046
2047
JANUARY 2023
Message Text and Description
Wellness test failed because of
top cover is missing.
Wellness test failed because of
drive power board has failed.
Wellness test failed because of
move media test failed.
Wellness test failed because of
drive communication test
failed.
Wellness test failed because
the barcode scanning test
failed.
Details and Solution
Install the bottom cover on the
bottom module of the library. Also
check the module interconnect
cabling and module power cabling. If
the controller module cannot detect
both a top and bottom cover the
robot will not move.
1.
Ensure that the drive power
boards are fully seated in the
module. See "Installing the New
Drive Power Board" in Spectra
Stack DC-DC Converter
Replacement
2. Power cycle the Library.
Check for obstructions in the
pathway of the robot such as a
cartridge sticking out. Verify module
alignment and frame alignment.
Check if the robotic assembly is stuck
in the lock mechanism. Move robotic
assembly apart from lock mechanism
and enable lock mechanism correctly.
Remove and reseat the drive tray to
ensure that the drive is fully seated.
If the issue persists then reset the
drive. Check the drive dump for
more information. See
Drive Logs on
Verify that there is no obstruction in
front of the barcode scanning module
on the cartridge table located on the
robotic assembly. If the error persists
replace the robotic assembly. See the
Spectra Stack Spool Robotic Replacement
Instruction.
235