CHAPTER 9 - EVENT CODES
Event Code
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
JANUARY 2023
Message Text and Description
Robotic spooling cable failure.
Cable to spooling mechanism
has failed.
Move command failed due to
spooling mechanism failure.
Exchange cartridge failed due
to spooling mechanism
failure.
Library test failed due to
robotic assembly problem.
Library test failed due to
spooling mechanism defect.
Drive power board has failed.
Some drives might be
powered off.
Multiple bottom covers
detected.
Multiple top covers detected.
Bottom cover missing.
Details and Solution
Ensure that the spooling cable is
fully seated in the controller module
and correctly connected to the
robotic assembly.
Review the test requirements and
retry the test. If the test continues to
fail, check for robotics obstructions
or other robotics problems.
Ensure that the spooling mechanism
is fully seated in the controller
module and installed correctly with
the robotic assembly.
1.
Ensure that the drive power
boards are fully seated in the
module. See "Installing the New
Drive Power Board" in Spectra
Stack DC-DC Converter
Replacement
2. Power cycle the library.
Remove all bottom covers except for
the bottom module in the library.
Remove all top covers except for the
top module in the library.
If the controller module cannot
detect both a top and a bottom cover,
the robotic mechanism will not
move.
1. Install the bottom cover on the
bottom module in library.
230
Instructions.
SPECTRA STACK LIBRARY
USER GUIDE
Need help?
Do you have a question about the Stack Tape Library and is the answer not in the manual?
Questions and answers