Spectra Stack Tape Library User Manual page 244

Table of Contents

Advertisement

CHAPTER 9 - EVENT CODES
Event Code
4025
4027
4028
4029
4030
4031
4041
4044
4054
JANUARY 2023
Message Text and Description
Library test failed due to a
cartridge error.
Library Test failed due to a
cartridge error.
Drive cannot use this media
due to it being an unknown or
unsupported format. Possibly
the media is the wrong
generation of media.
Incompatible media move
operation blocked by media
barcode ID check.
Move cartridge operation
failed due to media error.
Exchange media failed due to
media error.
Wellness test failed because of
power supply redundancy test
failed.
One of the Library tests failed
because of a source element or
destination element is
currently not accessible.
Chassis fan failed.
Details and Solution
1. Remove the cartridge and
inspect it for damage.
2. Retry the operation with
another cartridge.
Check that the LTO generation of the
tape cartridge is the same generation
indicated on the barcode label.
Remove cartridges which are not
compatible to your tape drives.
Check if Media barcode label is
matching LTO generation. Replace
label or remove incompatible media
from your system.
Remove the cartridge and inspect it
for damage. Retry the operation with
another cartridge.
Remove the cartridge and inspect it
for damage. Retry the operation with
another cartridge.
Ensure all power supplies are
installed properly (two per module),
and that each power supply is
connected to a valid power source.
Contact Spectra Logic Technical
Support. See
Logic on
page 11.
Check the chassis fan and replace the
fan if defective. See the
Fan Replacement Instructions.
244
Contacting Spectra
Spectra Stack
SPECTRA STACK LIBRARY
USER GUIDE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Stack Tape Library and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF