CHAPTER 9 - EVENT CODES
E
E
RROR
VENTS
Event Code
2000
2001
2002
2003
2004
JANUARY 2023
Message Text and Description
Failed to move cartridge.
Failed to exchange the
cartridge.
The initial module discovery
(detection of expansion
modules) failed.
The library's temperature has
exceeded the critical limit.
Library startup failed.
Details and Solution
Verify the source and destination
elements and retry the move
operation.
Verify that all expansion modules are
powered on and that the expansion
interconnect cables are properly
installed.
1. Verify that the chassis fan in
each module is functioning
2. Verify that the drive cover
plates are installed in all open
drive bays.
3. Verify that all power supplies
are installed and working
properly.
4. Verify that the ambient room
temperature is within specified
limits.
1. If the robotic assembly fails to
move through a certain area of
the library:
• Look through the window in the
front panel and see if there are any
obstructions.
• Verify that both magazines in that
module can be extended.
2. Verify that all modules have
power and that any expansion
modules are cabled correctly
with the expansion
interconnect cables.