CHAPTER 9 - EVENT CODES
Event Code
4013
4014
4015
JANUARY 2023
Message Text and Description
Exchange cartridge failed due
to a drive issue.
Library test failed due to a
drive issue.
Power supply has failed.
Redundancy is not available.
Details and Solution
2. Retry the operation with the
same source and destination. If
the problem persists, retry the
operation with a different
cartridge in the same drive.
3. Check the drive dump for
more information. See
Downloading Drive Logs on
page 203.
1. Retry the operation with the
same source and destination. If
the problem persists, retry the
operation with a different
cartridge in the same drive.
2. Check the library event log for
events associated with this
drive. See
on
page 195.
3. Check the drive dump for
more information. See
Downloading Drive Logs on
page 203.
1. Verify the test parameters and
then retry the test.
2. Check the library event log for
events associated with this
drive. See
on
page 195.
3. Check the drive dump for
more information. See
Downloading Drive Logs on
page 203.
1. Ensure that all power supplies
are installed properly.
242