CHAPTER 9 - EVENT CODES
Event Code
2035
2036
2037
2038
2039
2040
2041
2042
JANUARY 2023
Message Text and Description
Initialization failure due to
robot gripper positioning
error.
Unintended termination of
application process.
Robotic firmware version
upgrade failed.
Lost connection to Module.
Cartridge left in robot gripper,
unable to be moved to any
open location.
Wellness test failed with
critical error.
Wellness test failed because of
unit lock failed.
Wellness test failed because of
top cover is missing.
Details and Solution
Check for obstructions in the gripper
pathway of the robot such as a
cartridge sitting in the shuttle of the
robot.
Reboot or power cycle system.
Reboot or power cycle system. If the
problem persists, contact Spectra
Logic Technical Support. See
Contacting Spectra Logic on
Ensure that all modules are powered
and have the interconnect cable
properly attached. Reboot or power
cycle the system.
Enable EE ports and ensure that
some of them are free. Then power
cycle library. If still failing, open
covers and remove cartridge
manually from gripper.
See codes 2041-2051.
Ensure that the alignment
mechanism is engaged in every
module that is above another module
in the library
Install the top cover on the top
module of the library. Also check the
module interconnect cabling and
module power cabling. If the
controller module cannot detect both
a top and bottom cover the robot will
not move.
234
page 11.
SPECTRA STACK LIBRARY
USER GUIDE