Mounting
This section outlines the various options for:
•
•
•
•
•
Rack Mounting the TLP 1000MV
Underwriters Laboratories Guidelines for Rack Mounting
The following Underwriters Laboratories (UL) guidelines are relevant to the safe installation of
these products in a rack:
Elevated operating ambient temperature — If the unit is installed in a closed or multi-unit
rack assembly, the operating ambient temperature of the rack environment may be greater than
room ambient temperature. Therefore, install the equipment in an environment compatible with
the maximum ambient temperature (Tma: +122 °F, +50 °C) specified by Extron.
Reduced air flow — Install the equipment in the rack so that the equipment gets adequate air
flow for safe operation.
Mechanical loading — Mount the equipment in the rack so that uneven mechanical loading
does not create a hazardous condition.
Circuit overloading — Connect the equipment to the supply circuit and consider the effect
that circuit overloading might have on overcurrent protection and supply wiring. Give appropriate
consideration to the equipment nameplate ratings when addressing this concern.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted equipment. Pay
particular attention to supply connections other than direct connections to the branch circuit
(such as the use of power strips).
Rack Mounting the TLP 1000MV
The TLP 1000MV can be mounted in any standard 19-inch equipment rack, using the optional
Extron RM 1000M rack mounting kit. Follow the instructions provided with the kit.
Rack Mounting the TLP 1000MV
Wall Mounting the TLP 1000MV
Furniture Mounting the TLP 1000MV
Desktop Mounting the TLP 1000TV
Removing the TLP 1000TV base for VESA Mounting
TLP 1000MV and TLP 1000TV • Mounting