Mode 5 - Reset To Factory Defaults; Activation; Result; Purpose And Notes - Extron electronics TLP 1000MV User Manual

Touchlink touchpanel control systems
Hide thumbs Also See for TLP 1000MV:
Table of Contents

Advertisement

Mode 5 — Reset to Factory Defaults

Activation

Hold down the Reset button for approximately 9 seconds until the Reset LED blinks three times
(at 3, 6, and 9 seconds). Then release and press Reset momentarily (less than 1 second) within 1
second.

Result

This mode performs a complete reset to factory defaults (except the firmware). It does everything
that mode 4 does and, in addition:
NOTE:

Purpose and Notes

This mode is useful if you want to start over with configuration and uploading, and also to replace
events.
Removes button and touchpanel configurations.
Resets all IP options
Removes all scheduling options.
Removes and clears all files from the touchpanel
Nothing happens if the momentary press does not occur within 1 second.