Mode 3 — Run or Stop Events

Activation

Hold down the Reset button for approximately 3 seconds until the Reset LED blinks once. Then
release and press Reset momentarily (less than 1 second) within 1 second.

Result

This mode turns events on or off.
NOTE:

Purpose and Notes

This mode is useful for troubleshooting.
Mode 4 — Reset all IP Settings
Activation
Hold down the Reset button for approximately 6 seconds until the Reset LED blinks twice (at 3
seconds and 6 seconds). Then release and press Reset momentarily (less than 1 second) within
1 second.
Result
This mode:
NOTE:
Purpose and Notes
This mode enables you to set IP address information, using ARP and the MAC address.
Nothing happens if the momentary press does not occur within 1 second.
Enables ARP capability.
Resets the IP address to the factory default (192.168.254.254).
Resets the subnet to the factory default.
Resets the gateway address to the factory default.
Turns port mapping back to the factory default.
Turns DHCP off.
Turns events off.
Nothing happens if the momentary press does not occur within 1 second.
TLP 1000MV and TLP 1000TV • Reset Modes