38. Verify the settings for each option. To change a value, type the number
39. Type 1 and ENTER to change the IP Address. Type the new address and
40. Type 2 and ENTER to change the current Date. Enter the date in the
41. Type 3 and ENTER to change the current Time. Use either 12-hour or
42. Type 4 and ENTER to change the Default Trap IP. Enter the IP address
43. Type 5 and ENTER to change the Default Gateway IP address for your
44. Type 6 and ENTER to change the Subnet Mask for your network. Type
45. Type 7 and ENTER to change the Read Community option for your
46. Type 8 and ENTER to change the Write Community option for your
47. When you have changed all options to the appropriate value, type d to
48. A configuration summary appears:
58
5. Default Gateway
6. Subnet Mask
7. Read Community
8. Write Community
Enter Selection (-(previous), q(uit), d(one), <1>: 1
The Controller's IP address must not be the same address as the Default
trap IP or the Default Gateway IP address.
corresponding to the menu option.
If no changes are needed, or when all necessary changes have been
made, type d and ENTER. Proceed to MR9600 Controller Setup step
ENTER.
format: <month>/<day>/<year>, and press ENTER.
24-hour format, and press ENTER.
that the controller will send traps to without requiring the IP to be
logged in to the supervisor. Press ENTER. If this value is set to 0.0.0.0
(default), then traps are only sent to supervisors that log in to the
controller. Type the IP address of the supervisor PC that you want to
send error and status information to, for example 192.168.4.150.
network. Type the address and press ENTER.
the address and press ENTER.
network. The default setting is public. Type the new setting and press
ENTER.
The Read/Write Community options are a security feature of SNMP,
which allows control over access of SNMP data by external users.
network. The default setting is public. Type the new value and press
ENTER.
complete the configuration.
IP Address:192.168.4.150
Date:10/4/2000
Time:10:24am
Default Trap IP:0.0.0.0
Default Gateway:0.0.0.0
Subnet Mask :0.0.0.0
Read Community:********
Write Community:********
Config CONTROLLER? (<y>, n):
:192.168.4.1
:0.0.0.0
:********
:********
#