Page 1
MultiModemManager Model CC4800 Card Cage Hardware Manual...
Page 2
Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.
1. No manual adjustments to the equipment are necessary for connection to mains power within rated voltage and frequency. 2. The power supply cord (or input screw terminals if a CC4800 48 Volt Card Cage) is intended to serve as the disconnect device. The socket-outlet must be installed near the equipment and be easily accessible.
CAUTION: For continued protection against risk of fire, replace with same type and rating of fuse. The fuse size is T7.0A, 250 V. For CC4800, CC4800/11, and CC4800/21: AC 100-240V, 50/60 Hz, 5-2.5 A CAUTION: For continued protection against risk of fire, replace with same type and rating of fuse.
Page 5
Requisitos de potencia C.A. 100-240 V, 50/60 Hz, 5-2,5 Amp ATTENCION: Para garantizar la protección continua frente al peligro de incendio, sustitúyase con un fusible del mismo tipo e iguales especificaciones de funcionamiento. Adviertase que los requisitos respecto a medidas de seguridad no quedan satisfechos a menos que este equipo eléctrico esté...
Page 6
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
You may control up to 254 MultiModemManager racks from a single PC running the MultiModemManager software, which operates under Windows™ 3.1. Model CC4800/11 consists of a card cage with a backplane of 48 RJ11 (6-pin modular) phone connectors, and one PS4800 power supply. It supports dial-up lines.
The fuse size is T7.0A, 250V. The rack back panel on your CC4800 48 Volt Card Cage does not appear as illustrated in Chapter Two of this manual. Instead of an AC Power outlet and fuse on the bottom right of the cage, you will find a 3-terminal power input strip and an hexagonal-shaped fuse holder.
Page 11
• only connect like circuits. In other words, connect SELV (Secondary Extra Low Voltage) circuits to SELV circuits and TN (Telecommunications Network) circuits to TN circuits. 1 - 3...
Hardware Installation Procedure WARNING: When the modem rack is connected to the phone lines, it is possible for hazardous voltages to be present within the modem rack. To avoid injury, all modems should be installed in the rack, and any card slot that does not have a modem in it should be fitted with a blank panel prior to making any connections from the rack to the phone lines.
Page 15
9. Determine the modem slot(s) to be used and remove front panel slot(s) if necessary. Insert the MultiModem cards. Align modem module in card guides and press firmly to mate the connectors. 10. Power on the rack. 2 - 3...
Figure 2-2. The optional RJ21 version of the back panel is shown in Figure 2-4; the optional RJ11 version is shown in Figure 2-5. Note: The CC4800 48 Volt Card Cage does not appear as illustrated. You will find a 3-terminal power input strip and hexagonal-shaped fuse holder instead of an AC Power outlet and fuse on the bottom right of the cage.
• 2-RJ11 (four-pin) female network connectors, • 48-RS232C/D female modem connectors, and • 1-female 3-prong Power cord connector; or if a 48 Volt CC4800 one 3- terminal power input strip. Refer to the appropriate Network interface card (NIC), PC, or modem manual for cable specs.
Figure 2-3. Back Panel (with CC48-21L Phone Line Interface Board) Note: The CC4800 48 Volt Card Cage does not appear as illustrated. You will find a 3-terminal power input strip and hexagonal-shaped fuse holder instead of an AC Power outlet and fuse on the bottom right of the cage.
RS232 Interface (SELV) Connectors Figure 2-4. Back Panel (with CC48-11 Phone Line Interface Board) Note: The CC4800 48 Volt Card Cage does not appear as illustrated. You will find a 3-terminal power input strip and hexagonal-shaped fuse holder instead of an AC Power outlet and fuse on the bottom right of the cage.
This chapter illustrates and describes the cables and connectors related to the MultiModemManager rack. These cables can be purchased from Multi-Tech Systems, any of its distributors, or from any cable manufacturer. RJ11 is readily available or may be purchased from Multi-Tech.
CA1432MR Line Cable Multi-Tech provides a standard line cable for connecting the MT1432MR or the MT 2834MR back panel phone line interface to the PSTN and/or leased lines. The DB25 (female) line cable and connector information is shown below. CA1432MR Line Cable - DB25 Female Connector (Rear View)
These 50-pin RJ21 connectors are used on racks with an RJ21 Dial-up Phone Line Interface Board. We provide this interface board to facilitate RJ21 hook-up by your local telephone company. Multi-Tech designation These numbers refer to the position of these connectors on the back panel of the rack as shown in Figure 2-3.
(CC48-21L) These 50-pin connectors are used on racks with an RJ21 Leased Line Phone Line Interface Board to simplify local telephone company installation. Multi-Tech designation These numbers refer to the position of these connectors on the back panel of the rack as shown in Figure 2-3.
4-Wire Receive Pair (CC48-21L) These 50-pin connectors are used on racks with an RJ21 Leased Line Phone Line Interface Board to simplify local telephone company installation. Multi-Tech designation These numbers refer to the position of these connectors on the back panel of the rack as shown in Figure 2-3.
MultiModemManager Rack is $395, $95 for a Power Supply, and $95 for a Rack Controller Card. These prices are valid at the time of this publication, but could change in the future. Multi-Tech pays the return freight. Send equipment to this address: MULTI-TECH SYSTEMS, INC.
Tech Support Multi-Tech has an excellent staff of tech support personnel available to help you get the most out of your Multi-Tech products. If you have any questions about the operation of this unit, please call Tech Support at 1-800-972-2439 (U.S.
Related Products and Documentation MultiModemManager Products MMM-Starter Starter Rack includes either (must specify) a CC4800/ 11 (phone connections through 48-RJ11 connectors, 6- pin modular) or CC4800/21 (phone connections through 6 RJ21 connectors, 50-pin amphenol) card cage, MR4800 controller module, one PS4800 power supply, AN301TP8 NIC and MMM software.