Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc., to notify any person or organization of such revisions or changes.
Federal Communications Commission Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
See your fax software manual for setup details. MultiTech Systems, Inc. CommPlete CC9600 AU7USA-31090-DE-E 04DU9-ISN, 04DU9-BN 6.0N RJ48C MultiTech Systems, Inc.
5. Cooling Requirements The ambient operating temperature of the CC9600 chassis is 0° C to 40° C. Important Safety Requirements • No manual adjustments to the equipment are necessary for connection to mains power within rated voltage and frequency.
• To reduce the risk of shock, all openings should be covered during normal operation of the equipment. • Both power cords must be removed to remove all power from the chassis. The power supplies are connected in parallel, so that both power supplies supply power to all power busses in the chassis. To remove all power from the left power supply, disconnect the left power cord;...
Vigtige Sikkerhedskrav • Det er ikke nødvendigt at foretage manuelle justeringer af udstyret, for at tilslutte udstyret til elektrisitetsuettet indenfor de navute spændingsfrekvensgreuser. • Strømforsyningsledningen er beregnet til at fungere som afbryder. Stikkontakten skal installeres nær ved udstyret og skal være let tilgængelig. •...
CC9600 Chassis User Guide Introduction The CC9600 chassis is the housing for the CommPlete Communications Server. It can contain one chassis controller module, two power supply modules (one is required, and two are recommended), four independent RASCard servers, and 96 modems (12 modem cards, with eight modems per card) or four PRI cards.
Environmental Dimensions Weight Limited Warranty CommPlete Communications Server CC9600 Temperature range: 0°–40° C (32°–104° F) Humidity range: 0–95% (noncondensing) 31.1 × 48.3 × 36.8 cm (12.25 × 19 × 14.5 in.) H × W × D 11 kg (25 lb.)
Page 14
CC9600 Chassis User Guide CommPlete Communications Server...
The CC9600 is designed to be installed in a standard 19-inch-wide rack cabinet. Figure 1 shows a fully loaded chassis with one controller card, two power supplies, and a full complement of RASCards and modem cards.
Advice should be obtained from a competent engineer before such a connection is made. Installation • If the chassis is installed in a closed or multi-rack assembly, the operating temperature of the rack environment may be greater than the ambient temperature. Be sure to install the chassis in an environment that is compatible with the maximum rated ambient temperature.
The rear of the CommPlete Communications Server provides connections to power, communications lines, and configuration hardware, as shown in Figure 2. Only the power connectors are part of the CC9600 chassis. The other connectors are mounted on removable cards or modules, and are documented in their respective user guides.
CC9600 Chassis User Guide Appendix A Installing 3rd Party Software This appendix describes how to install the following software packages on the CommPlete Communication Server: • Citrix WinFrame • Microsoft Windows NT • SCO UNIX ...
Page 21
16. Enter 210 for the I/O address and 10 for the IRQ for the first card; Enter I/O address 220 and IRQ 11 for the second card; Enter I/O address 230 and IRQ 12 for the third card. 17. Leave the port numbers at the default settings, unless you have a good reason to change them. 18.
CC9600 Chassis User Guide Installing Microsoft Windows NT Software on the CommPlete This procedure tells how to install the Microsoft Windows NT software package on the CommPlete Communication Server. This procedure can be performed only by using the optional DA96002 load card.
Installing SCO UNIX Software on the CommPlete This procedure steps you through the process of installing SCO UNIX software from The Santa Cruz Operation Inc.on the CommPlete system. This procedure can be performed only by using the optional DA96002 load card.
CC9600 Chassis User Guide Installing USL/Novell UNIXWare Software on the CommPlete This procedure steps you through the process of installing UNIXWare software from USL/Novell on the CommPlete system. This procedure can be performed only by using the optional DA96002 load card.