3.4.1

Perform the Automated Serial-based FTP Upload Procedure

1) Double-click FLSHCAT.EXE (filename or icon) on the PC desktop to
execute the FLASH UPLOAD utility program.
2) From the FLSHCAT dialogue box, select the pertinent
serial port used for communication between the PC and
the HPOD (this example selects COM1, as noted at
'A'.)
3) Do not select a Baud Rate ('B') other than the default
selection of 19200, unless otherwise instructed by
Comtech Technical Support.
4) Click 'Software Upload' ('
A. Select the firmware file for upload. Click 'Choose
File' then, once the Select a File Name dialogue
box opens, use the window on the right to navigate
to the desired folder. Finally, double-click on the
firmware file from the window on the left.
B. Once the file is selected, the upload will take place
– do not interrupt this upload process.
Updating Firmware
').
C
If the upload is not successful for any
reason (e.g., the comms cable is not
physically connected, the wrong COM
port is specified, the user
inadvertently interrupted the upload,
etc.), troubleshoot the setup as
needed, and then click on 'Repeat
Upload' or 'Go Back to Start' to
resume or retry the upload process.
HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
3–9
Revision 9
MN/HPOD.IOM