Comtech EF Data HPOD Installation And Operation Manual page 95

C, x, ku-bandhigh power outdoor amplifier
Hide thumbs Also See for HPOD:
Table of Contents

Advertisement

Command
Parameter
Number of
(Instruction
Type
Arguments
& Qualifier)
Remote
SBR=
4 bytes,
Baud Rate
alphanumeri
c
Summary
N/A
1 byte,
Fault Status
value of 0,1
Remote
SPA=
4 bytes,
Address
numeric
Set RTC
TIM=
6 bytes,
Time
numeric
Serial-Based Remote Product Management
Description of Arguments
Command or Query.
Set remote baud rate in the form xxxx, where:
9600 = 9600 baud
19K2 = 19200 baud
Example: SBR=9600'cr'
Note: When changing baud rates remotely the response to the
command will be returned using the same baud rate as that used
to send the command.
Query only.
Returns the condition of the summary fault relay where:
0 = Not Faulted (SumFLT_COM J6 pin K is connected to
SumFLT_NO J6 pin L, and SumFLT_NC J6 pin M is open)
1 = Faulted (SumFLT_COM J6 pin K is connected to
SumFLT_NC J6 pin M, and SumFLT_NO J6 pin L is open)
Example: <1/SFS?
>0001/SFS=0'cr''lf'
Command or Query.
Set Physical Address in the form xxxx, where:
xxxx = address between 0001 to 9999, resolution 0001
Example: SPA=0412'cr'
Command or Query.
Sets or returns the RTC time in the form hhmmss, where:
hh = hours, between 00 and 23;
mm = minutes, between 00 and 59,
ss = seconds, between 00 and 59
Example:(time = 23 hours, 12 minutes and 59 seconds since
midnight.):
<1/TIM=231259'cr'
>0001/TIM='cr''lf'
5–22
HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Query
Response to
(Instruction &
Command
Qualifier)
SBR=
SBR?
SBR?
N/A
SFS?
SPA=
SPA?
SPA?
TIM =
TIM?
TIM?
TIM*
Revision 9
Response to
Query
SBR=xxxx
(See
Description of
Arguments)
SFS=x
(See
Description of
Arguments)
SPA=xxxx
(See
Description of
Arguments)
TIM=xxxxxx
(See
Description of
Arguments)
MN/HPOD.IOM