Command
Parameter
Number of
(Instruction
Type
Arguments
& Qualifier)
Retrieve next
N/A
145 bytes,
5 unread
alphanumeri
Stored
c
Alarms
Serial-Based Remote Product Management
Description of Arguments
Query only.
Reports the five oldest stored events in the alarm log, and if there
are no events in the log the unit will reply with LNA*. All events
that are read from the log are also automatically removed from
the log.
Reply format:
YYYYYYYYYY ZZ mmddyy hhmmss'cr'
YYYYYYYYYY ZZ mmddyy hhmmss'cr'
YYYYYYYYYY ZZ mmddyy hhmmss'cr'
YYYYYYYYYY ZZ mmddyy hhmmss'cr'
YYYYYYYYYY ZZ mmddyy hhmmss'cr''lf'
Where:
YYYYYYYYYY is the fault description.
ZZ is the event type:
FT = Fault
OK = Clear
IF = Information
mmddyy hhmmss = date / time stamp.
Example:
<1/LNA?'cr'
>0001/LNA='cr'
LOG CLR IF 175503 052307'cr'
FAN #1 FT 175504 052307'cr'
OVR TMP FT 175504 052307'cr'
FAN #1 OK 175504 052307'cr'
IIC BUS FT 175504 052307'cr''lf'
5–17
HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Query
Response to
(Instruction &
Command
Qualifier)
N/A
LNA?
Revision 9
Response to
Query
LNA=YY..ss
(See
Description of
Arguments)