Comtech EF Data HPOD Installation And Operation Manual page 92

C, x, ku-bandhigh power outdoor amplifier
Hide thumbs Also See for HPOD:
Table of Contents

Advertisement

Command
Parameter
Number of
(Instruction
Type
Arguments
& Qualifier)
Redundancy
RED=
1 byte,
State
value of 0,
1, 2
Reference
REF=
3 bytes,
Oscillator
numeric
Tuning
Retrieve
N/A
22 bytes,
Equipment
alphanumeri
Type
c
Serial-Based Remote Product Management
Description of Arguments
Command or Query.
Set or report as ON or OFF the redundancy state, in the form x,
where:
0 = Off
1 = 1:1 Redundancy
2 = 1:2 Redundancy
Example:
<1/RED=1'cr'
>0001/RED='cr''lf'
Command or Query.
Adjusts the reference oscillator tuning voltage by sending a DAC
value in the form xxx, where:
xxx = numeric value from 0 to 255, and the default value is set to
87.
Example:
<1/REF=87'cr'
>0001/REF=
Note: This command sets the DAC value, but the actual
Reference Oscillator tuning voltage can be monitored using the
RMS command.
Query only.
Returns the Model Number and the version of the MnC firmware
installed in the unit.
Example:
<1/RET?'cr'
>0001/RET=CPA-300 VER: 1.0.3'cr''lf'
5–19
HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Query
Response to
(Instruction &
Command
Qualifier)
RED=
RED?
RED?
RED*
REF=
REF?
REF?
REF*
N/A
RET?
Revision 9
Response to
Query
RED =x
REF=xxx
(See
Description of
Arguments)
RET=x....x
(See
Description of
Arguments)
MN/HPOD.IOM

Advertisement

Table of Contents
loading

Table of Contents