Command
Parameter
Number of
(Instruction
Type
Arguments
& Qualifier)
Concise
N/A
25 bytes,
Alarm Status
alphanumeri
c
Concise
N/A
24 bytes,
Configuration
alphanumeri
Status
c
Serial-Based Remote Product Management
Description of Arguments
Query only.
Reports the Alarm status of the unit. Response is comma
delimited in the form a,b,c,d,e,f,g,h,I,j,k,I,m'cr''lf' where:
a thru k = 0 or 1
0 = OK
1 = FT
a = +24V Power Supply
b = +15V Power Supply
c = +10V-A Power Supply
d = +10V-B Power Supply
e = +7.5V Power Supply
f = +5V Power Supply
g = -5V Power Supply
h = Fan#1 State
i = Fan#2 State
j = Heatsink Temp
k = Shutdown
l = llC Status
m=Forward Power Alarm
Query only.
Reports the summarized version of RCS. Response is comma
delimited in the form aaaaa,b,c,d,e-e,fffff,g,'cr' where:
aaaaa = attenuation in dB
b = RF power amplifier state
c = mute state
0 = unmuted
1 = muted
d = online status
e-e = redundancy state and mode
fffff = gain offset in dB
g = AFR
5–13
HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Query
Response to
(Instruction &
Command
Qualifier)
N/A
CAS?
N/A
CCS?
Revision 9
Response to
Query
CAS=x....x
(See
Description of
Arguments)
CCS=x....x
(See
Description of
Arguments)
MN/HPOD.IOM