Comtech EF Data HPOD Installation And Operation Manual page 148

C, x, ku-bandhigh power outdoor amplifier
Hide thumbs Also See for HPOD:
Table of Contents

Advertisement

Arguments
Command
Parameter
(Instruction
Command
Code and
Type
Response
Qualifier)
to Query
Redundancy
N/A
1 byte,
State
value of 0,
1, 2
Set switch
SSW=
1 byte,
position
value of 0,1
Gain Offset
GOF=
5 bytes,
numerical
Set Backup
SBO=
7 bytes,
Offset
numerical
Appendix B
for
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
or
ASCII codes between 48 and 57)
Query only.
Returns the current redundancy state in the form x, where:
0 = OFF
1 = 1:1 Redundancy
2 = 1:2 Redundancy
Command only.
For 1:1 systems only(sent to either unit):
Only used when system is in MANUAL redundancy mode
(RAM=0, both units).
Forces switch position in the form x, where:
1 = Forces switch to put SSPA 1 online
2 = Forces switch to put SSPA 2 online
Command or Query.
Set or query the adjusted attenuation level, in 0.25 dB
increments, in a 1:1 redundancy system so power is equal
between the online and offline units when a switchover occurs,
in the form xx.xx.
Example: GOF=02.00'cr'
Command or Query.
Set or query the adjusted attenuation level, in 0.25 dB
increments, in a 1:2 redundancy system so power is equal
between the online and offline units when a switchover occurs.
In the form #,xx.xx where:
# = 1 or 2
xx.xx = level, in 0.25 dB increments
Examples: SBO=1,02.00'cr' or SBO=2,02.50'cr'
HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
B–9
Response to
Query
Response to
Command
(Instruction
(Target to
Code and
(Target to
Controller)
Qualifier)
Controller)
N/A
RED?
RED=x
(see
Description of
Arguments
for details)
SSW=
N/A
N/A
SSW?
GOF=
GOF?
GOF =xx.xx
GOF?
(See
Description of
GOF*
Arguments
for details)
SBO=
SBO?
SBO=#,xx.xx
SBO?
(See
Description of
SBO*
Arguments
for details)
MN/HPOD.IOM
Revision 9
query