3) Enter the User name and password (the default for both is comtech):
Use the LRS remote command to set the Ethernet remote control access parameter:
Use default remote command LRS=3 for Serial + Ethernet control
Use remote command LRS=2 for Ethernet control only.
4) If necessary, use the IPA remote command to set a unique IP address.
1) Each HPOD must have a unique IP address assigned before
2)
Ethernet-Based Remote Product Management
connection to a network. If the IP address needs to be changed from
the factory default setting, use the IPA=xxx.xxx.xxx.xxx.yy remote
command, where 'xxx.xxx.xxx.xxx' is a valid IP address on the
network where the unit will be installed, and 'yy' is the range
(typically, yy=24).
If you change the IPA value, make sure to shut off and restart the
unit; then, start a new Telnet session using the new IP address.
HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
4–7
Revision 9
MN/HPOD.IOM