Command
Parameter
Number of
(Instruction
Type
Arguments
& Qualifier)
Set RTC
DAT=
6 bytes,
(Real-Time-
numeric
Clock) Date
Retrieve
N/A
256 bytes
Firmware
Number
Mute State
MUT=
1 byte,
value of 0,1
Online Status ONL=
1 byte,
value of 0, 1
Serial-Based Remote Product Management
Description of Arguments
Command or Query.
Set clocks in the form mmddyy, where:
mm = month of the year, between 01 and 12
dd = day of the month, between 01 and 31
yy = year, between 00 and 96 (2000 to 2096)
Example:(date = April 24, 2003):
<1/DAT=042403'cr'
>0001/DAT='cr''lf'
Query only.
Returns the firmware type loaded into the unit.
Example: <1/FRW?'cr'
>0001/FRW='cr'
BULK=FW12524'cr'
MnC =FW12522'cr'
FPGA=FW10788'cr''lf'
Note: the RET? Query returns the MnC firmware revision.
Command or Query.
Mutes the unit, in the form x, where:
0 = Disabled
1 = Enabled
2 = Unit muted due to discrete control lines. Query
only.
Example: <1/MUT=1'cr'
Command or Query.
Online status (applies only to redundancy), in the form x, where:
0 = Disabled
1 = Enabled
Example: <1/ONL=1'cr'
>0001/ONL='cr''lf'
5–16
HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier
Query
Response to
(Instruction &
Command
Qualifier)
DAT=
DAT?
DAT?
DAT*
N/A
FRW?
MUT=
MUT?
MUT?
MUT*
response
ONL=
ONL?
ONL?
ONL*
Revision 9
Response to
Query
DAT=xxxxxx
(See
Description of
Arguments)
FRW=x...x
(See
Description of
Arguments)
MUT=x
(See
Description of
Arguments)
ONL=x
MN/HPOD.IOM