R&S TSMA6 User Manual page 189

Autonomous mobile network scanner
Hide thumbs Also See for TSMA6:
Table of Contents

Advertisement

®
R&S
TSMA6
Configuring downconverter R&S TSME30DC/TSME44DC - "Downconverter Configuration"
Figure C-5: Tab "Downconverter Configuration"
IF Output Receiver Configuration
Specify the configuration of the IF output connectors of the R&S TSME30DC/
TSME44DC.
RF Input Antenna Configuration
Specify the configuration of the RF input antenna connectors of the R&S
TSME30DC.
For R&S ViCom and R&S ROMES, the API only allows the configuration of fre-
quencies of activated antenna ports. For the overlapping frequency range 27 GHz
to 27.5 GHz, the "mmWAve Antenna 1" is used by default.
Specify the configuration of the RF input antenna connectors of the R&S
TSME44DC.
For R&S ViCom and R&S ROMES, the API only allows the configuration of fre-
quencies of activated antenna ports.
Accept Configuration
To confirm the current configuration settings, select the "Accept Configuration" button.
User Manual 4900.8057.02 ─ 11
Managing scanner device with R&S TSME Device Manager
Bypass Antenna (< 6 GHz)
mmWave Antenna 1 (24 GHz to 27.5 GHz)
mmWave Antenna 2 (27 GHz to 30 GHz)
Bypass Antenna (< 6 GHz)
mmWave Antenna 1 (24-44 GHz)
189