System Examination
Continuous Reading
Regardless of the displayed image (through/freeze), a 33.3 ms
max. delay occurs before loading the image after the TRIG B sig-
nal is input.
Standard Processing Time (values for OMRON's standard codes)
QR Code (Normal Mode)
Data Matrix (Normal Mode)
Note The data here are standard values. When installing, calculate
the processing time according to the actual specifications and
confirm the value in the actual operating environment. The pro-
cessing time is displayed in the upper-right corner of the screen
when reading is performed in MON (monitor) or RUN mode.
Matrix size
21 X 21 (Version 1)
29 X 29 (Version 3)
41 X 41 (Version 6)
Matrix size
10 X 10
14 X 14
26 X 26
Section
Processing time
160 ms
200 ms
260 ms
Processing time
180 ms
190 ms
250 ms