Omron V530-R150E-2 Operation Manual page 145

Table of Contents

Advertisement

SET (Setting) Mode
1. Read DM (Pattern)
Set the reading conditions and the conditions for searching for a
model when reading Data Matrix codes.
Reading Settings
A
Symbol Color
B
Right &Left Reverse
C
Code Size
D
Number of Retries
E
Endpoint Calculation
F
Pixel Skipping
G
Correlation
1
Select the color of symbol.
Black
Black symbol printed on white base.
(Default
setting)
White
White symbol printed on black
base.
2
Select whether Right & Left Reverse of Data Matrix codes is
necessary.
ON
For reading an image after reflection, or through the
back of a transparent material, such as glass.
OFF
For normal reading (from the front of the object)
(Default
setting)
3
Select the code size.
(10
10 to 26
4
Select the number of retries to be made if the reading is NG.
A fresh image will be obtained and reading performed for the
number of times specified.
(0 to 9; Default setting: 0.)
5
If Endpoint Calculation is set to ON, in cases where only two
endpoints of the finder pattern can be found, an estimate will
be made for the third point and reading will be performed.
(Default setting: ON.)
26, 8
32; Default setting: 10
Section
6-1
j
:
Black
j
:
OFF
j
: 10 10
j
:
0
j
:
ON
:
[4]
:
[55]
10)
133

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

V530-r150ep-2

Table of Contents