Omron V530-R150E-2 Operation Manual page 187

Table of Contents

Advertisement

System
6-4-6
Error Method
A V530-R150 does not perform reading while the BUSY terminal
is ON even when TRIG A is input. Set whether or not to turn ON
the ERR terminal if a trigger signal is sent while the BUSY termi-
nal is ON to inform the external device that the trigger has not
been accepted.
2
Set each item.
3
Select End before leaving this screen.
1
ERR ON (Default setting)
Reading is not performed while the BUSY terminal is ON re-
gardless of TRIG A input.
When TRIG A is input with the correct timing, the ERR termi-
nal turns OFF.
OFF
ERR terminal does not turn ON when TRIG A is input while
BUSY terminal is ON. Reading is not performed.
OFF