Regular Inspections
To maintain the V530-R150 in the best condition, perform the fol-
lowing regularly.
Inspection Items
Power Supply
Ambient
Temperature
Ambient Humidity
Installation
Note
184
Lightly wipe off dirt with a soft cloth.
Clean the lens and indicators with a cloth for a lens or air brush.
Details
The voltage measured at the power supply
terminals on the terminal block must be
24 VDC (+10%, –15%).
The operating ambient temperature inside the
cabinet must be between 0 to +50 C.
The operating ambient humidity inside the
cabinet must be between 35 to +85%.
Each cable connector must be correctly
inserted and locked.
The cameras must be firmly secured.
The camera lens mounts must be firmly
secured.
1. Turn OFF the power and take safety precautions before
conducting inspections.
2. Do not use thinners or benzene.
Section
7
Required Tools
Circuit Tester
Thermometer
Hygrometer
Phillips screw
driver