Power Supply and Ground
2-3-3
Wiring the Power Supply
Caution
!
Use a DC power supply with safe extra low-voltage circuits on
the secondary side. Excessively high voltages can result in elec-
tric shock.
Power supply
Use a power supply with the following specifications. We recom-
mend using OMRON's S82K-01524 Power Supply.
Use a power supply with the following specifications when con-
necting the V530-R150 and F150-M05L LCD Monitor to one
power supply. We recommend using OMRON's S82K-05024
Power Supply.
24 VDC
Note
Output current
Power supply voltage
Output current
Power supply voltage
1. Wire the Power Supply Unit independently of other devices.
In particular, keep the power supply wired separately from
inductive loads.
2. Keep the power supply cable as short as possible.
3. If UL recognition is required, use a UL class II power supply.
Section
0.6 A min.
24 VDC+10%, –15%
1.6 A min.
24 VDC+10%, –15%