SET (Setting) Mode
Procedure
146
1
Select 2. Image Analysis .
0. Image Adjust
1. Read QR (Normal)
2. Image Analysis
2
Select either Line Bright X or Line Bright Y as required.
Display Pixel Value
Line Bright (X)
Line Bright (Y)
Image Magnifier
Measure Length
3
Select the gray edge level for black and white judgment.
(1 to 127)
Press the ENT Key to change the cursor to fill one digit or
character. Use the Left/Right Keys to change line and use
the Up/Down Keys to change the gray edge level.
Gray Edge Value [32]
Cancel
Register
4
Select Register . The Line Bright screen will be displayed.
5
Move the cross cursor with the Up/Down/Left/Right Keys
and press the ENT Key when the cursor is at the beginning
point of the required line. Press the SHIFT Key together with
the above keys to move the cursor faster.
6
Select the end point of the line.
Use the Left/Right Keys (Line Bright (X)) or the Up/Down
Keys (Line Bright (Y)) to move the cross cursor to the end
point of the required line and press the ENT Key.