Omron V530-R150E-2 Operation Manual page 219

Table of Contents

Advertisement

Error Codes and Countermeasures
9-2-3
Data Matrix Reading in Pattern Mode
Error Code
E160
Timing pattern detection
error 1 (No finder patterns
were detected for models 1
or 2)
E161
Timing pattern detection
error 2 (32 or more finder
patterns were detected for
models 1 or 2)
E170
Finder pattern detection
error 1 (No finder pattern
was detected for model
ABC)
E171
Finder pattern detection
error 2 (32 or more finder
patterns were detected for
model ABC)
Description
Countermeasures
No timing pattern was detected.
The timing pattern may be stained or dam-
aged. Check the condition of the timing
pattern.
The correlation value may be too high.
Decrease the correlation value.
A model may not be registered. Confirm
that a model is registered.
A model may have been registered with an
incorrect code size. Re-register the
model.
Too many timing patterns (32 or more)
were detected.
The correlation value may be too low.
Increase the correlation value.
No finder pattern was detected.
The finder pattern may be stained or dam-
aged. Check the condition of the finder
pattern.
The correlation value may be too high.
Decrease the correlation value.
A model may not be registered. Confirm
that a model is registered.
A model may have been registered with an
incorrect code size. Re-register the
model.
Model registration may not have been per-
formed in the optimum way. Re-register
the model with reference to page 128.
Too many finder patterns (32 or more)
were detected.
The correlation value may be too low.
Increase the correlation value.
Model registration may not have been per-
formed in the optimum way. Re-register
the model with reference to page 128.