System
Host Link
When Host link is selected for the communications mode, it is
possible to communicate with host devices such as Program-
mable Controller with host link format via RS-232C.
MON (Monitor) Mode
Receives command inputs, but the reading results are not out-
put.
RUN Mode
Possible to input commands and output the reading results.
2
Set the number of seconds (1 to 120 s) before a timeout er-
ror occurs. (Default setting: 5 s)
A
B
C
D
E
1
Set the area from which the V530-R150 reads commands.
Select I/O, HR (holding relay), LR (link relay), DM (data
memory), or None. If no read area is set, commands will not
be automatically read from the Programmable Controller by
executing the TXD instruction in the ladder program. (The
default setting is I/O.)
2
Set the first word to read in area specified above (0 to 9995).
(Default setting: 0)
3
Set the write area where the V530-R150 writes the result.
Select I/O, HR (holding relay), LR (link relay), DM (data
memory), or None (No writing). (The default setting is I/O.)
4
Set the first word to write in the area specified (0 to 9996).
(Default setting: 100)