SET (Setting) Mode
140
2
Judge Coincidence is a function that performs coincidence
judgment of reading data.
Up to 4 standard data can be registered.
Select Data (0 to 3) to register the standard data and then
set to ON .
Data 0 to 3: The data read in the next trigger is registered
as the number of standard data.
Verify:
Every time reading is performed, the regis-
tered standard data and reading data are veri-
fied.
The judgment result is output to terminal
blocks (DO0 to 3) and RS-232C (Normal).
OFF:
No judgement is performed. (Default setting)
Clr Data:
All registered data is cleared.
3
When Data History is turned ON, the following four items are
counted and displayed on the screen.
The counted values are maintained even when the power is
turned OFF if the data is saved to flash memory.
To reset the Data History, set to OFF and select Register .
(The default setting is OFF.)
Number of readings
Number of OK readings
Reading accuracy
(Number of OK readings B Number of readings
Error codes
4
When Reading Accuracy is turned ON, one trigger performs
ten readings.
The reading accuracy and the data from the 10th reading
are displayed on a screen and output to RS-232C (Normal).
(The default setting is OFF.)