(Example 2) To update the RTP port range:
a.
Enter the following text into the document, if not already present:
{"network":{"rtpstartport":2048,"rtpendport":3329}}
rtpstartport":2048 and rtpendport":3329 is the range.
b.
Replace the values with the desired range.
NOTES:
The port range may differ depending on the phone system being used.
The default port range for VoIP RTP traffic on the DMP Plus Series is
50000-50999.
Save the file as voipConfig.conf.
3.
4.
Navigate to the System tab of the VoIP web page (see
In the Import System Configuration panel, click the Browse button (see figure 65,
5.
on page 87) to locate the voipConfig.conf file created in the previous steps.
1
6.
Click the Import button (
notification will appear once the settings have applied successfully.
) to update the DMP Plus Series with the new settings. A
2
DMP 64 Plus • Internal Web Pages
System Tab
on page 87).
89