X6)
=
0
Mute Status —
=
X6!
Group Master Group Number —
X6@
=
Group Fader Setting — dB, value in 0.1 dB increments using a 10x multiplier and negative numbers, but not decimal places.
The valid range depends on the type of gain block that is assigned to the group number X5( specified in the command:
-180 to 800 (-18 dB to +80 dB)
-1000 to 120 (-100.0 dB to +12.0 dB)
-120 to 120 (-12.0 dB to +12.0 dB)
-1000 to 0 (-100.o dB to +0.0 dB)
NOTE:
Leading zeros are ignored.
=
X6#
Group Fader Increment/decrement —
=
X6$
Group Fader Soft Limit —
X6%
=
6
Group Type —
= Gain,
X6^
=
Meter Group Number —
X6&
=
Unsolicited Meter Rate (responses per second) —
=
X6*
Unsolicited Meter Group Setting —
unsolicited meter value responses;
X6(
=
Group Master Meter Group Number —
X7)
=
Source Mode —
X7!
=
Update Status —
X7@
=
Meter Level — -150.0 dBFS to 0.0 dBFS (
X7#
=
Output Mode —
X7$
=
Gate Monitoring Status —
0
X7%
=
Meter Status —
=
X7^
Monitoring Threshold —
=
0000-2000
X7&
Meter Value —
=
X7*
Meter Relative to Threshold —
X7(
=
Signal level when gate is opened or closed —
X8)
=
1-8
Line Number —
X8!
=
Appearance Number —
X8@
=
Phone Number — No spaces allowed. Valid characters are
X8#
0
=
Return Code —
X8$
=
Operating State —
1
= Unmute
= Mute
1
64
through
dB value, in 0.1 dB increments, to raise or lower a group fader.
dB value, in 0.1 dB increments.
12
21
= Mute,
= Meter
1
64
through
0
disables unsolicaited meter responses,
0
at power on.
1
through
0
= Disabled
1
= File/Tone Playback: Player 1
2
= File/Tone Playback: Player 2
3
= File/Tone Playback: Player 3
4
= File/Tone Playback: Player 4
5
= File/Tone Playback: Player 5
6
= File/Tone Playback: Player 6
7
= File/Tone Playback: Player 7
8
= File/Tone Playback: Player 8
0
1
= Disabled
= Enabled
1500
0000
to
0
= Disabled
1
= USB 1 Tx: Left Channel
2
= USB 1 Tx: Right Channel
3
= USB 2 Tx: Left Channel
4
= USB 2 Tx: Right Channel
5
= USB 3 Tx: Left Channel
0
= Gate monitoring disabled
1
= Meter off
= Meter on
0
0001-2000
= Disabled
0.0
200.0
=
to -
dBFS
0
= Above threshold
0000-1023
1-8
1
(where
is originating two-party call)
1
= Ok
= Fail
0
1
= Enable
= Disable
1-10
1
. Default is
.
1-64
64
9
= USB 1 Rx: Left Channel
10
= USB 1 Rx: Right Channel
11
= USB 2 Rx: Left Channel
12
= USB 2 Rx: Right Channel
13
= USB 3 Rx: Left Channel
14
= USB 3 Rx: Right Channel
15
= USB 4 Rx: Left Channel
16
= USB 4 Rx: Right Channel
17
= VoIP Line 1 Rx
)
6
= USB 3 Tx: Right Channel
7
= USB 4 Tx: Left Channel
8
= USB 4 Tx: Right Channel
9
= VoIP Line 1 Tx
10
= VoIP Line 2 Tx
11
= VoIP Line 3 Tx
1024
= Gate monitoring enabled
= Signal threshold to monitor (-0.1 to -100.0 dBFS)
1
= Equal to or below threshold
= gate closed, ≥1024 = gate opened
0-9
*
#
,
,
.
DMP 64 Plus• SIS Configuration and Control
specifies/enables a meter group for
18
= VoIP Line 2 Rx
19
= VoIP Line 3 Rx
20
= VoIP Line 4 Rx
21
= VoIP Line 5 Rx
22
= VoIP Line 6 Rx
23
= VoIP Line 7 Rx
24
= VoIP Line 8 Rx
12
= VoIP Line 4 Tx
13
= VoIP Line 5 Tx
14
= VoIP Line 6 Tx
15
= VoIP Line 7 Tx
16
= VoIP Line 8 Tx
42