Power Supply Wiring
A 12 VDC, 2.0 A power supply is provided with the DMP 64 Plus. Follow the instructions
and figure 9 to wire the provided 2-pole captive screw connector to your power supply.
CAUTION: The DC output cables must be kept separate from each other while the
ATTENTION:
ATTENTION:
SECTION A–A
Figure 9.
1.
2.
3.
4.
5.
power supply is plugged in. Remove power before wiring.
Les câbles de sortie CC doivent être séparés les uns des autres
tant que la source d'alimentation est branchée. Coupez l'alimentation avant
d'effectuer les raccordements.
Do not connect any external power supplies until you have read the Attention
•
notifications starting below.
•
Veuillez lire les encadrés « Attention » à partir ci-dessous avant de brancher
une source d'alimentation externe.
A
Smooth
Ridges
3/16"
A
(5 mm) Max.
Power Input Wiring
Cut the DC output cord to the length needed.
Strip the jacket to expose 3/16 inches (5 mm) of the conductor wire (see figure 9).
Ensure the connections have the correct polarity as shown in the figure above. The wire
with ridges is the ground wire.
Slide the exposed ends of the wire into the captive screw connector and secure by
tightening the screws.
Use the supplied tie wrap to strap the power cord to the extended tail of the connector.
ATTENTION:
The length of the exposed (stripped) copper wires is important. The ideal
•
length is 3/16 inch (5 mm). Longer bare wires can short together. Shorter
wires are not as secure in the connectors and could be pulled out.
La longueur des câbles exposés est primordiale lorsque l'on entreprend de
•
les dénuder. La longueur idéale est de 5 mm (3/16 inches). S'ils sont un
peu plus longs, les câbles exposés pourraient se toucher et provoquer un
court circuit. S'ils sont un peu plus courts, ils pourraient sortir, même s'ils sont
attachés par les vis captives.