Verbose Modes; Simple Instruction Set Control; Host-To-Unit Instructions; Device-Initiated Power-Up Message - Extron electronics DMP 64 Plus User Manual

Audio products mixers and processors
Hide thumbs Also See for DMP 64 Plus:
Table of Contents

Advertisement

Verbose Modes

Telnet connections can be used to monitor for changes that occur, such as SIS commands
from other Telnet sockets or serial port changes. For a Telnet session to receive change
notices, the Telnet session must be in verbose mode 1 or 3. In verbose mode 1 or 3, the
Telnet socket reports changes in messages that resemble SIS command responses (see
Set verbose mode
Tagged and Untagged Responses
When a query command is sent in verbose mode 0 or 1, only the "untagged" value is
returned. When a query command is sent in other verbose modes, the response is "tagged"
and resembles the response to a set command.
Examle: The gain query command
appear depending on the verbose mode:
NOTE: All query responses listed in this guide are shown untagged.

Simple Instruction Set Control

Host-to-Unit Instructions

SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command character sequence. When a command is valid, the
transmitter executes the command and sends a response to the host device. All responses
from the transmitter to the host end with a carriage return and a line feed (CR/LF = ]] ),
which signals the end of the response character string. A string is one or more characters.

Device-Initiated Power-Up Message

When the device completes its start-up, it issues the following message to the host:
© Copyright 2019-2022, Extron Electronics DMP 64 Plus {model}
60-nnnn-nn
Day, DD MMM YYYY HH:MM:SS
The DMP 64 Plus sends the boot and copyright messages under the following
circumstances:
on page 46).
Untagged (verbose 0 or 1): 626
Tagged (verbose 2 or 3): DsG40000*626
and the gain value.
]
]
{model} is the full model name (for example, DMP 64 Plus C V AT).
Vx.xx is the firmware version number
60-nnnn-nn is the part number of the unit
If the DMP 64 Plus is off and RS-232 connection is already set up (the PC is cabled to
the DMP 64 Plus and a serial communication program such as DataViewer is open), the
connected unit sends these messages via RS-232 when first powered on.
The DMP 64 Plus sends the boot and copyright messages when a Telnet connection to
the DMP 64 Plus is opened via Telnet, but not via RS-232. If using a Telnet connection,
the copyright message, date, and time may be followed by a password prompt.
E
}
G40000AU
is sent. The following responses
]
, just the gain value with no other information.
]
, the type of query sent, the OID queried,
DMP 64 Plus• SIS Configuration and Control
Vx.xx
,
,
36

Advertisement

Table of Contents
loading

Table of Contents