g) SETTING
Make various settings.
1) Pth
Turn on or off the head pulse rank control function.
Default: OFF
2) RTC
Set RTC (real time clock) after replacing the lithium battery on the main controller PCB.
3) PV AUTO JUDGE
Sets ink saver mode.
Default: OFF
4) NETWORK
See "e-maintenance/imageWARE Remote" for detail.
5) E-RDS
See "e-maintenance/imageWARE Remote" for detail.
6) HEAD DOT INF
Select whether to display the message as the result of non-discharging nozzle detection or not.
Default: ON
h) INITIALIZE
Clear the [DISPLAY] histories, [ADJUST] settings, [COUNTER] values, and other parameters.
WARNING
ERROR
JAM
ADJUST
W-INK
CARRIAGE
PURGE
INK-USE CNT
W-INK-CHG CNT
HEAD-CHG L CNT
HEAD-CHG R CNT
HDD BOX PASS. ALL FOLDERS
PARTS-CHG
CNT
PARTS
COUNTER
7-26
Display
DATE yyyy/mm/dd
Set date
TIME
hh:mm
Set time
Number of non-discharging
nozzle (nozzle/2,560-nozzles)
0-99
100-319
320 or more
Display
Initialize the history of WARNING.
(All displayed contents of [DISPLAY] > [WARNING] will be initialized.)
Initialize the history of ERROR.
(All displayed contents of [DISPLAY] > [ERROR] will be initialized.)
Initialize the history of JAM.
(All displayed contents of [DISPLAY] > [JAM] will be initialized.)
Initialize the value of band adjustment (by user) and head adjustment.
The automatically adjusted value will not be initialized.
Initialize the remaining capacity (%) of the maitenance cartridge.
(Clear [COUNTER] > [PRINTER] > [W-INK])
Initialize the counter related to carriage unit.
(Clear [COUNTER] > [CARRIAGE])
Initialize the counter related to purge unit.
(Clear [COUNTER] > [PURGE])
Initialize the consumption amount of ink.
(Clear [COUNTER] > [INK-USE2], and count up [COUNTER] > [CLEAR] > [CLR-INK
CONSUME])
Initialize the maintenance cartridge replacement frequency.
(Clear [COUNTER] > [EXCHANGE] > [MTC EXC.], and count up [COUNTER] > [CLEAR]
> [CLR-MTC EXC.])
Initialize the printhead L replacement frequency.
(Clear [COUNTER] > [EXCHANGE] > [HEAD L EXC.], and count up [COUNTER] >
[CLEAR] > [CLR-HEAD L EXC.])
Initialize the printhead R replacement frequency.
(Clear [COUNTER] > [EXCHANGE] > [HEAD R EXC.], and count up [COUNTER] >
[CLEAR] > [CLR-HEAD R EXC.])
Initialize the BOX password of all folders of the hard disk drive to factory default.
FOLDER xx
Initialize the BOX password of FOLDER xx of the hard disk drive to factory default.
PARTS xx-x
xx-x: Unit number of consumable parts
(For details, refer to "Maintenance and Inspection" > "Consumable Parts")
Initialize the consumable part replacement frequency.
(Clear [COUNTER] > [EXCHANGE] > [xx-x EXC], and count up [COUNTER] > [CLEAR]
> [CLR xx-x EXC.])
PARTS xx-x
xx-x: Unit number of consumable parts
(For details, refer to "Maintenance and Inspection" > "Consumable Parts")
Initialize the counter amount of the consumable parts.
(Clear [COUNTER] > [PARTS CNT.] > [COUNTER xx-x])
* After replacing the consumable part, be sure to execute this menu.
Description
ON
Displays a message to check the
printing.
Displays a message to check the head. -
Displays a message to replace the head.
Description
OFF
-

Hide quick links: