Polycom ATX Integrator's Guide
Verifying the Camera Alignment
5 - 24
Open the camera controls for the camera attached to codec 3 and select 2
3
from the Select Camera drop-down list. This will result in the codec
sending black video.
After both cameras are aligned, make sure Preset 95 is selected and then
4
press Set to save Preset 95 for all the codecs.
Note that no alignment is necessary for Preset 94. Preset 94 has the same
alignment as Preset 95 and will be automatically set by the Telepresence Tool.
To verify the camera alignment:
Press Preview on the Telepresence Tool Camera Alignment screen to
1
recall the presets for each of the presets.
For each preset, verify the pan, zoom, and tilt:
2
— Pan and zoom: Verify that the camera alignment marks on the table
are barely visible at the edges each display.
— Tilt: Verify that the top edge of the table is positioned at the correct
height as specified previously.
Check if the Ceiling Microphones Arrays are visible at the top of the
3
displays. If so, you should not change the camera alignment; rather, you
should raise the microphones (if possible) so that they do not appear.
Figure 5-22
Camera Control Screen
Polycom, Inc.