1. INTRODUCTION
Submersible pumps are multi-stage centrifugal pumps that are de-
signed as their submersible electric motors work under the water. Mo-
tor bearings are lubricated with the water that is filled inside the sub-
mersible electric motor and cooling operation for the bearings is pro-
vided by the water in the well that's flowing around the body of motor.
THE REPRODUCTION, EVEN PARTIAL, OF THE ILLUSTRATIONS
AND/OR TEXT HEREIN IS FORBIDDEN.
The following symbols are used throughout the instruction booklets:
WARNING!
Risk of damaging the pump or the system
Risk of injuring people or damaging things
Risks of an electrical nature
2. CONTENTS
1. INTRODUCTION
2. CONTENTS
3. MANUFACTURER IDENTIFICATION DATA
4. GUARANTEE AND TECHNICAL ASSISTANCE
5. TECHNICAL-PRODUCTION CHARACTERISTICS
6. INSTALLATION, DISMANTLING AND TRANSPORTATION
7. ELECTRICAL CONNECTION
8. USE AND STARTING
9. MAINTENANCE AND REPAIRS
10. DISPOSAL
11. SUPPLIED TECHNICAL DOCUMENTATION
12. DECLARATION OF CONFORMITY
3. MANUFACTURER IDENTIFICATION DATA
3.1 MANUFACTURER DATA
VANSAN Makina San. Tic. A.Ş.
10035 Sok. No:10 A.O.S.B. Cigli – IZMIR / TURKEY
Phone : +90 232 376 76 50
Assistance Service:
Please, let's contact Sales Representative/Distributor.
3.2 MOTOR-DRIVEN PUMPS
See plates
SUBMERSIBLE PUMP NAMEPLATE (FIG. 3.1):
4. GUARANTEE AND TECHNICAL ASSISTANCE
THE GUARANTEE IS RENDERED NULL AND VOID IF THE IN-
STRUCTIONS GIVEN IN THIS BOOKLET ARE NOT ADHERED
TO AND/OR IF ANYONE OTHER THAN PERSONNEL FROM OUR
HELP CENTRES INTERVENES
Once you have received the motor-driven pump, make sure that the
packaging is not broken or seriously damaged. If it is, immediately in-
form the person who delivered it. After extracting the motor pump from
its packaging, make sure that it was not damaged during transporta-
tion. I Check the motor-driven pump plate to ensure that the indicated
characteristics are those requested by you.
The following parts, being normally subject to wear, have a limited
guarantee:
• bearings
• mechanical seals and/or gasket
If a fault that is not listed in the "TROUBLESHOOTING" table (chapter
10.1.) occurs, please contact the nearest authorized retailer.
5. TECHNICAL-PRODUCTION CHARACTERISTICS
5.1. DESCRIPTION AND USE OF MOTOR-DRIVEN PUMP
Description:
SUBMERSIBLE CENTRIFUGAL MOTORDRIVEN PUMPS
Pump Model: BSP SS
5.2. USE FOR WHICH PUMPS ARE DESIGNED
The pumps can be used for lifting and distributing clean water or water
with a sand content not exceeding the limit given in chap. 6.4.
The submersible motor-driven pumps are used:
a) Water supply from borehole wells
b) Agricultural irrigation
c) Industrial applications
d) Mining fountains
e) Pressure boosting
Use the motor-driven pumps based on their technical
specifications.
5.3. USE FOR WHICH PUMPS ARE NOT DESIGNED
The submersible motor-driven pumps must not be made to
without water. If there is any chance of the waterbed lowering to a
point where the pump will be exposed, you will need to install a mini-
mum-level sensor as a safety measure.
5.4. SPECIFICATIONS
BSP series pumps in versions with a water-bath motor and the non-re-
turn valve is built into the pump;
PUMP SPECIFICATION
U.M.
Max. temperature of
°C
liquid pumped
Max. amount of sand
g/m
3
in suspension
Max. size of solids
mm
Type of liquid pumped
5.5. INFORMATION ON AIRBORNE NOISE
Given the type of use, the motor-driven pumps do not exceed an
A-weighted sound pressure emission level of 70 dB (A).
5.6. RATING PLATES
The manufacturer reserves the right to make changes
EN
work
BSP SS
50 (please follow motor spe-
cifications)
50
none
clean water or water with a
sand content not exceeding
the limit given in chap. 6.4.
9