F EMERGENCY PROCEDURE
Follow this procedure only in case of emergency such as a critical error occurred
during the Boot Block Flash BIOS update (when using UBIOS utility program or if
you meet one of the following symptoms at anytime:
1.
No POST code on a power up (when using a POST card).
2.
System stops at POST 41(when using a POST card) and associated beep code is
generated (Refer to Section E.1).
3.
Board does not boot, even after usual hardware and connection verifications.
F.1 HOW TO RUN EMERGENCY PROCEDURE
F.1.1 To run an EMERGENCY PROCEDURE, proceed as
follows:
1.
Remove battery jumper.
2.
Disable the Power Fail Detection function.
3.
Connected a 1.44MB floppy drive (drive A) to the board, and insert the
EMERGENCY diskette, that you previously created, in it.
4.
Power on the board. (Note that no VGA is present during this procedure.)
5.
Boot block flash update will be completed when the POST code 55 is displayed
(when using a POST card) or the associated beep code sounds (indicated in
Section E-5).
6.
After the procedure is successfully completed, power down the board, install
your battery and Power Fail Detection jumpers.
The boot block flash BIOS should be correctly programmed and the system
should run properly.
NOTE
See section F.2 Generate a Emergency Floppy Diskette.