10.8 Power supply part
• Rated supply voltage
• Range of use voltage
• Power supply frequency:50/60Hz(Sharing)
• Power consumption:
Power-supply
voltage
Usually
100V AC
Under 15VA
240V AC
Under 25VA
When you "OFF" the backlight by the LCD sleep function.
※
10.9 Structure
• Installation method:Panel burial installation(Vertical panel)
• Installation posture:The rear side 0
• The installation panel thickness:2
• Material:Polycarbonate, glass10%, UL94-V0
• Color:Black
• Externals size:150(W)×144(H)×181.8(D)mm
• Mass:About 1.0kg(Input 3 channel, option none)
• External terminal stand:M3.5 screw terminal
10.10 Normal operating condition
• Power-supply voltage:100
• Ambient temperature:0
• Surrounding humidity:20
• Vibration:10
60Hz 0.2m/s
~
• Impact:The impact is not allowed.
• Warm-up time:30 min or more after power supply is turned on.
10.11 Others
• Clock:
With calendar function (Christian era)
Accuracy ±50ppm or less (About 2 min / month difference)
However, it doesn't contain the error margin at power supply ON / OFF.
•Memory backup:
The parameter is preserved in an internal flash memory.
The clock backup with the built-in lithium battery.
(Battery life when no energizing, about 5 year)
• Insulation resistance:Over 500V DC 20MΩ(Between each terminal
• Electric strength:
Between input terminals ... 500V AC / 1 min
Between power supply terminal-G terminals ... 2000V AC / 1 min
Between input terminal-G terminals ... 500V AC / 1 min
240V AC
:100
~
264V AC
:85
~
Power consumption
LCD OFF ※
Under 12VA
Under 22VA
30°, The right and left horizontal
~
7mm
~
240V AC
~
50℃
~
80%RH(Non condensing)
~
2
10-6
G terminals)
-
Need help?