Measure
NOTICE
optoCONTROL 2600
Response:
Byte 1
Byte 2
„0"
„D"
0x27
0xA0
0x00
0x00
Possible error codes:
0x00000004
Too much data received
0x0000000A
Error on writing to the RAM
0x0000000B
Incorrect data transmitted, see Valid values
0x0000000C
Incorrect measurument program number
Avoid error!
> Data are not accepted!
6.6.3.11 Save Option Data
SAVE OPT RAM TO FLASH
Name
Description:
With this command the currently valid option data is written from
the main memory to the flash memory.
Command:
Byte 1
Byte 2
„+"
„+"
„0"
„D"
0x29
0x20
Response:
Byte 1
Byte 2
„0"
„D"
0x29
0xA0
0x00
0x00
Possible error coder:
0x00000006
Flash access error
Byte 3
Byte 4
„C"
„1"
0x03
0x00
0x00
0x00
Byte 3
Byte 4
„+"
0x0D
0x0D2B2B2B
„C"
„1"
0x00
0x00
Byte 3
Byte 4
„C"
„1"
0x03
0x00
0x00
0x00
hex
Remark
0x3143444F
0x0003A027
Without error
0x00000000
Error code
hex
0x3143444F
0x00002029
hex
Remark
0x3143444F
0x0003A029
Without error
0x00000000
Error code
Page 50
Need help?
Do you have a question about the optoCONTROL 2600 and is the answer not in the manual?
Questions and answers