Mode Of Operation - WAGNER AquaCoat 5010 GA 5000EAW Operating Manual

Air spraying system for non-ignitable liquids
Table of Contents

Advertisement

VERSION 03/2018

5.7.2 MODE OF OPERATION

The GA 5000EAW spray gun may only be operated with the control units designed for that purpose.
GA 5000EAWIC
M
AA / SA
CA
B_06007
GA 5000EAWIC
Open valves
The piston in the drive is charged with control
air and moves toward the rear. This ensures that
the air valve which releases the shaping and
atomizing air is opened first. The product valve
is then opened with a mechanical delay. In this
position, the pressurized coating product is
applied to the work piece.
Close valves
The piston is relieved, and the product valve
closes due to the pressure spring which presses
against the product valve tappet. The air valve
is then closed, again with a spring force and
mechanical delay.
Shaping air
The relationship between shaping air and atomizing
air is set using the shaping air regulator (6).
High voltage
– High voltage is activated when the VM 5020WA control unit is switched on.
– The high voltage can be adjusted at the VM 5020WA and can be adapted to the paint or to the spraying
object.
ORDER NUMBER DOC 2369735
Pneumatic Diagram
Description
SA
Shaping air
AA
Atomizing air
SA
CA
Control air
M
Product
AA
N
Nozzle
M
CA
SA
AA
GA 5000EAWEC
Open valves
First, the external air valve, which enables
the shaping and atomizing air, is opened. The
diaphragm in the drive is then charged with
control air and moves toward the rear, opening
the product valve. In this position, the pressurized
coating product is applied to the work piece.
Close valves
If the control air is deactivated, the product valve
closes due to the pressure spring.
The air valve is then closed externally.
Shaping air/atomizing air
The shaping air pressure and the atomizing air
pressure are set externally via separate pressure
regulators. Both air flows are supplied separately,
which allows them to be set separately.
GA 5000EAWEC
SA
AA
B_06008
40

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aquacoat 5020 ga 5000eaw

Table of Contents