Adjusting The Spray Angle - WAGNER AquaCoat 5010 GA 5000EAW Operating Manual

Air spraying system for non-ignitable liquids
Table of Contents

Advertisement

VERSION 03/2018
Spray gun
7. If the spray gun is subjected to external control air (red), the nozzle is opened.
8. If the high voltage is switched on, the displays (21) and (22) on the control unit change
from point to bar display, i.e. the actual value of the high voltage (21) and the actual
value of the spray current (22) are displayed.
The high voltage can only be switched on and off with the "Stand-by" push button (3)
if high voltage is switched on via the external control cable.
9. Spray on a test object.
10. Adjust the product pressure regulator (10) and external atomizing air in accordance
with the nozzle and object.
Rule of thumb: Set atomizing air pressure approx. three times higher than the
product pressure.

7.4.2 ADJUSTING THE SPRAY ANGLE

GA 5000EAWIC
The spray pattern can be adjusted to suit the object being sprayed using the shaping air
regulation on the side of the gun (see image).
GA 5000EAWEC
The spray pattern can be adjusted to suit the object being sprayed using the external
shaping air (see image).
+
Shaping air/shaping air
regulation opened.
ORDER NUMBER DOC 2369735
See Chapter 7.4.2.
-
B_06153
Shaping air/shaping air
regulation closed.
Round-jet method
Open shaping air / shaping air regulation.
AWR 5000: The size of the air cap should
match with the nozzle size.
Flat-jet method
59