Product Pressure Test; Check Spray Pattern - WAGNER AquaCoat 5010 GA 5000EAW Operating Manual

Air spraying system for non-ignitable liquids
Table of Contents

Advertisement

VERSION 03/2018

11.1.2 PRODUCT PRESSURE TEST

Connect the product hose to the spray gun.
Test the seal of the spray gun with suitable medium (e.g., flushing agent or Marcol 52) and
a maximum pressure of 0.8 MPa; 8 bar; 116 psi. Increase the pressure gradually while doing so.
Observe the following gun components:
Product connection, nozzle body, product valve (no post-spraying).
DANGER
Exploding gas / air mixture!
Danger to life from flying parts and burns.
Never spray into a closed tank.
Ground the tank.

11.1.3 CHECK SPRAY PATTERN

Check spray pattern in accordance with Chapter 7.4.2.