Review counter status since last service carried out on gun
22
26
25
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
µA
R3
18
17
6
5
7.4.12.2 "CARRY OUT SERVICE" DISPLAY
26
25
80
100
60
80
R1
40
60
20
40
R2
10
20
kV
µA
R3
ORDER NUMBER DOC 2369735
Procedure
27
1. Press the "Service" button (25) to
access the service menu. LED (26)
lights up.
2. Actuate the push button R2 (17) for
a short time; the LED (18) display
lights up.
3. Read off display in the LED display (27).
In the example, 46 hours have passed
POWER
POWER
0
1
since realization of the last spray gun
service. The bar display to the left (22)
indicates that 50% of the set interval
AquaCoat
time has passed.
B_03384
4. By keeping push button (5) pressed
2
down, the display in the LED display
(27) can be set to "0" (reset after
expiry of the set interval limit).
Prerequisite
The "Service interval limit" function is
activated (see Chapter 7.4.12.1).
"Service spray gun"
Once the time for the defined maintenance
interval has expired, the LED display (26)
starts to flash.
The flashing service display merely acts
POWER
POWER
0
1
as a warning. You can continue working
without any limitations.
AquaCoat
B_03385
69