COMPONENTS

AquaCoat with TOPFINISH DD10 double diaphragm pump
1
21
11
2
19
15
16
Designation
1 AquaCoat cabinet
2 Cabinet door
3 VM 5020WA control unit
4 GA 5000EAW automatic gun
(max. of 2 guns possible)
5 EAW product hose from product pressure
generator to spray gun (max. of 2 connections)
8 Air inlet with ball valve
9 Inlet for mains cable
10 Grounding terminal (input: grounding cable)
11 Product pressure generator (pump)
12 Relief combination
13 Suction system
14 Metallic product tank
ORDER NUMBER DOC 2369735
10
9
8
(20)
17
26
12
22
3
23
(29)
18
Designation
15 Grounding bolt on the cabinet door
16 Grounding band in the cabinet door
17 Electrical door switch
18 Pneumatic door switch
19 Door locking device engaging
20 Air hose, 8 mm (not used)
21 Air hose, 10 mm (product pressure generator)
22 Potential equalization lines, orange (4 pieces)
23 Control cable
26 Return line
27 Atomizing air hose (blue)
The atomizing air can be supplied externally or
from the control unit.
28 External control air hose (red)
29 External shaping air hose (only with GA  5 000EAWEC)