WAGNER AquaCoat 5010 GA 5000EAW Operating Manual page 75

Air spraying system for non-ignitable liquids
Table of Contents

Advertisement

VERSION 03/2018
Pin no. Designation
3 out
Fault output
4 in *
DC kV in
6 out
DC kV out
7 out
DC µA out
* If the external voltage set value specification function is to be used, parameter C12 must be set to "on" at the
VM 5020WA control unit (see Chapter 7.5.1).
Analog output
The analog outputs are not power outputs, but merely signal outputs.
ORDER NUMBER DOC 2369735
Description
If there is a fault, +24 V DC is issued at pin 3 in reference to pin 8 (ground).
Maximum current 0.5 A
Set value specification for high voltage. *
Analog d.c. voltage input at pin 4 in reference to pin 8 (ground).
0.1 V corresponds to 1 kV
8.0 V is a maximum specification and corresponds to 80 kV
Output of current actual voltage.
Analog d.c. voltage output at pin 6 in reference to pin 8 (ground).
0.1 V corresponds to 1 kV
8.0 V is a maximum specification and corresponds to 80 kV
Output of current actual spraying current.
Analog d.c. voltage output at pin 7 in reference to pin 8 (ground).
0.1 V corresponds to 1 μA
10.0 V is a maximum specification and corresponds to 100 μA
75

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aquacoat 5020 ga 5000eaw

Table of Contents