8.1.3 FLUSHING AND CLEANING THE SYSTEM

NOTICE
Liquid in air tube!
Functional faults caused by swollen seals.
Discharge current to ground
Always point the spray gun down when cleaning.
Ensure that neither lacquers nor cleaning or flushing agent enters the air duct.
When taking a break from work or when stored for a longer period, the spray gun
should be positioned with the adapter pointing downwards.
Flush regularly
The AquaCoat spray system must be cleaned and rinsed out every day.
The cleaning and flushing agents used must be compatible with the working material.
WARNING
Incompatibility of cleaning/flushing agent and working medium!
Risk of explosion and danger of poisoning by toxic gases.
Examine the compatibility of the flushing and cleaning agents and working media on
the basis of the safety data sheets.
ORDER NUMBER DOC 2369735
No high voltage.
B_06150
77